Removal and Replacement Procedures
Compaq ProLiant DL380 Generation2 Server Maintenance and Service Guide 2-57
COMPAQ CONFIDENTIAL Codename: Magna Part Number: 203840-003 Last Saved On: 1/28/02 1:12 PM
System Board
To remove the system board:
1. Power down the server. See the Powering Down the Server section in this chapter.
2. Extend or remove the server from the rack. See the Preparation Procedures section in
this chapter.
3. Remove the access panel. See the Server Access Panel section in this chapter.
4. Remove the air baffle. See the Air Baffle section in this chapter.
5. Remove the PCI riser cage. See the PCI Riser Cage section in this chapter.
6. Remove all hot-plug fans. See the Hot-Plug Fan section in this chapter.
7. Remove the front fan bracket. See the Front Fan Bracket section in this chapter.
8. Remove any SDRAM DIMMs. See the DIMMs section in this chapter.
9. Remove the processors. See the Processors section in this chapter.
CAUTION: Discard the heatsink after you remove it from the processor. The heatsink is for
one-time use only; after use the thermal interface material is degraded and does not provide
proper thermal dissipation.
10. Remove the PPMs. See the PPMs section in this chapter.
11. Remove the Smart Array 5i Controller. See the Smart Array 5i Controller section in
this chapter.
12. Remove the battery. See the Battery section in this chapter.
13. Disconnect all cables connected to the system board.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP ProLiant DL380 - G2 Server and is the answer not in the manual?

HP ProLiant DL380 - G2 Server Specifications

General IconGeneral
Form Factor2U Rackmount
CPUIntel Pentium III or Xeon
StorageUp to 6 hot-plug SCSI drives
Network ControllerIntegrated 10/100TX Ethernet
Power SupplyDual redundant hot-plug
Expansion Slots6 PCI (4x 64-bit, 2x 32-bit)

Related product manuals