[SwitchA-XGigabitEthernet0/0/3] smart-link flush receive control-vlan 10 password
simple 123
[SwitchA-XGigabitEthernet0/0/3] quit
# Configure Switch B.
<SwitchB> system-view
[SwitchB] interface xgigabitethernet 0/0/3
[SwitchB-XGigabitEthernet0/0/3] smart-link flush receive control-vlan 10 password
simple 123
[SwitchB-XGigabitEthernet0/0/3] quit
# Configure Switch C.
[SwitchC-smlk-group2] flush send control-vlan 10 password simple 123
[SwitchC-smlk-group2] quit
Step 6 Enabling the Functions of the Smart Link Group
# Configure Switch A.
[SwitchA] smart-link group 1
[SwitchA-smlk-group1] smart-link enable
[SwitchA-smlk-group1] quit
# Configure Switch C.
[SwitchC] smart-link group 2
[SwitchC-smlk-group2] smart-link enable
[SwitchC-smlk-group2] quit
Step 7 Create Monitor Link groups and add the uplink and downlink interfaces to the Monitor Link
groups.
# Configure Switch A.
[SwitchA] monitor-link group 1
[SwitchA-mtlk-group1] smart-link group 1 uplink
[SwitchA-mtlk-group1] port xgigabitethernet 0/0/3 downlink 1
# Configure Switch B.
[SwitchB] monitor-link group 2
[SwitchB-mtlk-group2] port xgigabitethernet 0/0/1 uplink
[SwitchB-mtlk-group2] port xgigabitethernet 0/0/3 downlink 1
Step 8 Set the revertive switching interval of the Monitor Link groups.
# Configure Switch A.
[SwitchA-mtlk-group1] timer recover-time 10
[SwitchA-mtlk-group1] quit
# Configure Switch B.
[SwitchB-mtlk-group2] timer recover-time 10
[SwitchB-mtlk-group2] quit
Step 9 Verify the configuration.
[SwitchA] display smart-link group 1
Smart Link group 1 information :
Smart Link group was enabled
Wtr-time is: 30 sec.
There is no Load-Balance
There is no protected-vlan reference-instance
DeviceID: 0025-9e80-2494 Control-vlan ID: 10
Member Role State Flush Count Last-Flush-Time
----------------------------------------------------------------------
XGigabitEthernet0/0/1 Master Active 1 0000/00/00 00:00:00 UTC