[17] PIO jog velocity (Parameter No.26)
No. Name Symbol Unit Input Range
Default factory
setting
26 PIO Jog Velocity JOGV
mm/s
[deg/s]
1 to 250 (250 or less
of actuator
maximum speed)
In accordance
with actuator
The setting of JOG operation velocity when the set in the JOG velocity / inching distance
switchover signal JVEL is set to OFF.
Set an appropriate value in Parameter No.26 in accordance with the purpose of use.
[18] Movement command type (Parameter No.27)
No. Name Symbol Unit Input Range
Default factory
setting
27 Movement Command Type MCT -
0 : Level
1 : Edge
0
Set the input methods for the start signal (ST0 to ST6, or ST0 to ST2 if PIO Pattern = 5) when
PIO Pattern 4 = Solenoid Valve Mode 1 (7-point type) and PIO Pattern 5 = Solenoid Valve
Mode 2 (3-point type).
Set Value Input Method Description
0 Level
The actuator starts moving when the input signal turns ON.
When the signal turns OFF during movement, the actuator will
decelerate to a stop and complete its operation.
1 Edge
The actuator starts moving when the rising edge of the input signal
is detected. The actuator will not stop when the signal turns OFF
during the movement, until the target position is reached.
[Level System]
[Edge System]
Move command input (ST0 to ST6)
Movement complete (PE0 to PE6)
Actuator movement
Target Position
Stop
Move command input (ST0 to ST6)
Movement complete (PE0 to PE6)
Actuator movement
Target Position
Chapter 8 Parameter