3 - INFORMATION FOR SET UP KID 80 SIV
EN
3 - Pag. 19 / 26
no.17 Speed reduction in
manual mode
Defines the speed value by which
the bar pusher moves in manual
mode. This value is expressed as a
percentage of the maximum speed.
Parameters:
A - Speed reduction in manual mode
Subparameters:
B - Forwards slowly
C - Forwards fast
D - Backwards slowly
E - Backwards fast
no. 72 Speed reduction during
bar change
Defines the speed value by which
the bar pusher moves during the
bar change cycle in the phases
described by B, C, D, E
subparameters. This value is
expressed as a percentage of the
maximum speed.
Parameters:
A - Speed reduction during bar
change
Subparameters:
B - From collet entry slowdown to
pulse window end
C - Pulse backwards
D - Facing to limit stop
E - Facing jog
71
no. 71 Speed
reduction
in manual mode
DEFAULT VALUE
PROGRAMMABLE
VALUE
KID KID
A
/ 0÷100
B
15.0 0÷100
C
50.0 0÷100
D
20.0 0÷100
E
50.0 0÷100
72
no. 72 Speed
reduction
during bar change
DEFAULT VALUE
PROGRAMMABLE
VALUE
KID KID
A
/ 0÷100
B
6.0 0÷100
C
20.0 0÷100
D
10.0 0÷100
E
28.0 0÷100