2 - INFORMATION FOR USE KID 80 SIV
EN
2 - Pag. 61 / 66
16 - AXIAL DISPLACEMENT NOT LOCKED (S1221 Off)
Warning: THE AXIAL DISPLACEMENT SENSOR IS NOT ACTIVE.
CAUSE SOLUTION
16
16 Error: axial
displacement
not locked
The axial displacement device is not
locked.
Lock the axial displacement device.
The sensor is faulty. Replace the sensor.
Incorrect reading of the sensor.
Check the distance between the sensor
and the relevant cam.
17 - MOTOR THERMAL CIRCUIT BREAKERS (E11.7)
A MOTOR THERMAL CIRCUIT BREAKER HAS TRIPPED.
CAUSE SOLUTION
17
17 Error: motor thermal
circuit breakers
The oil pump overheating has
occurred.
Make sure that the involved motor can
run freely and check the correct
thermal calibration (according to the
amperage).
Check the motor input voltage.