Parameter Groups
‑104‑
F0-21
Frequency offset of auxiliary frequency source upon superposition
Address:
0xF015
Min.:
0
Unit:
Hz
Max.: F0‑10 Data type: UInt16
Default:
0
Change: In real time
Value Range:
0.00 Hz to F0‑10
Description
This parameter defines the offset of the auxiliary frequency during superposition.
It is used to adjust the auxiliary frequency upon minimum frequency reference
signal when the frequency is set by an external analog signal (voltage or current).
F0-22
Frequency reference resolution
Address:
0xF016
Min.:
1
Unit:
‑
Max.: 2 Data type: UInt16
Default:
2
Change:
At stop
Value Range:
1: 0.1 Hz
2: 0.01 Hz
Description
This parameter defines the decimal places of the frequency reference.
F0-23
Retention of digital setting of frequency upon stop
Address:
0xF017
Min.:
0
Unit:
‑
Max.: 1 Data type: UInt16
Default:
0
Change: In real time
Value Range:
0: Non‑retentive
1: Retentive
Description
0: Non‑retentive
F0‑08 (preset frequency) is set through the operating panel and the frequency is
modified by using the â–² and â–¼ keys or UP and DOWN of terminals. When the AC
drive stops, the modification will be cleared.
1: Retentive
F0‑08 (preset frequency) is set through the operating panel and the frequency is
modified by using the â–² and â–¼ keys or UP and DOWN of terminals. When the AC
drive stops, the modification will be retained.

Table of Contents

Other manuals for Inovance MD500-PLUS Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Inovance MD500-PLUS Series and is the answer not in the manual?

Inovance MD500-PLUS Series Specifications

General IconGeneral
BrandInovance
ModelMD500-PLUS Series
CategoryDC Drives
LanguageEnglish

Related product manuals