Parameter Groups
‑110‑
Min.:
50
Unit:
%
Max.: 100 Data type: UInt16
Default:
86
Change: In real time
Value Range:
50.0% to 100.0%
Description
Asynchronous motor core saturation coefficient 1
F1-12
Asynchronous motor core saturation coefficient 2
Address:
0xF10C
Min.:
100
Unit:
%
Max.: 150 Data type: UInt16
Default:
130
Change: In real time
Value Range:
100.0% to 150.0%
Description
Asynchronous motor core saturation coefficient 2
F1-13
Asynchronous motor core saturation coefficient 3
Address:
0xF10D
Min.:
100
Unit:
%
Max.: 170 Data type: UInt16
Default:
140
Change: In real time
Value Range:
100.0% to 170.0%
Description
Asynchronous motor core saturation coefficient 3
F1-14
Asynchronous motor core saturation coefficient 4
Address:
0xF10E
Min.:
100
Unit:
%
Max.: 180 Data type: UInt16
Default:
150
Change: In real time
Value Range:
100.0% to 180.0%
Description
Asynchronous motor core saturation coefficient 4
F1-17
Synchronous motor axis D inductance
Address:
0xF111
Min.:
0.01
Unit:
mH