Parameter Groups
‑122‑
0: Digital setting (F2‑10)
1: AI1
2: AI2
3: AI3
4: Pulse reference (DI5)
5: Communication
6: Min. (AI1, AI2)
7: Max. (AI1, AI2)
8: Digital setting (F2‑12)
Description
0: Digital setting (F2‑10)
The torque upper limit in speed control mode is set by F2‑10 (digital setting of
torque upper limit in speed control).
1: AI1
The torque upper limit is input by current or voltage signal through the AI1. The
frequency is calculated according to the preset AI curve.
2: AI2
The torque upper limit is input by current or voltage signal through the AI2. The
frequency is calculated according to the preset AI curve.
3: AI3
The torque upper limit is input by current or voltage signal through the AI3. The
frequency is calculated according to the preset AI curve.
4: Pulse reference (DI5)
The torque upper limit in speed control mode is set through the DI5. The
frequency is calculated based on the curve of the relationship between the pulse
frequency and running frequency.
5: Communication
The main frequency is set through communication. The running frequency is
input through remote communication. The AC drive must be equipped with a
communication card to communicate with the host controller. This mode applies
to remote control or centralized control systems of multiple equipment.
6: Min. (AI1, AI2)
The torque upper limit in speed control mode is the smaller value between AI1
and AI2 inputs.
7: Max. (AI1, AI2)
The torque upper limit in speed control mode is the larger value between AI1 and
AI2 inputs.
8: Digital setting (F2‑12)
The torque upper limit in speed control mode is set by F2‑12 (torque upper limit
reference in speed control (generating)).