Parameter Groups
‑129‑
Description
F2-36
Single motor inertia (kg*m
2
)
Address:
0xF224
Min.:
0.001
Unit:
kg*m
2
Max.: 50 Data type: UInt16
Default:
0.001
Change:
At stop
Value Range:
0.001 kg*m
2
to 50.000 kg*m
2
Description
F2-37
Inertia auto-tuning maximum frequency
Address:
0xF225
Min.:
20
Unit:
%
Max.: 100 Data type: UInt16
Default:
80
Change:
At stop
Value Range:
20% to 100%
Description
F2-38
Inertia auto-tuning acceleration time
Address:
0xF226
Min.:
1
Unit:
s
Max.: 50 Data type: UInt16
Default:
10
Change:
At stop
Value Range:
1.0s to 50.0s
Description
F2-39
Bandwidth 1 of speed loop dynamic optimization test
Address:
0xF227
Min.:
1
Unit:
Hz
Max.: 200 Data type: UInt16
Default:
5
Change: Unchangeable
Value Range:
1.0 Hz to 200.0 Hz

Table of Contents