EasyManua.ls Logo

Inovance MD500-PLUS Series - 2.4 F3 V;f Control Parameters

Inovance MD500-PLUS Series
718 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Parameter Groups
‑133‑
0.110.0
Description
F2-52
Decoupling control
Address:
0xF234
Min.:
0
Unit:
Max.: 1 Data type: UInt16
Default:
0
Change:
At stop
Value Range:
0: Disabled
1: Enabled
Description
F2-53
Generating power limit
Address:
0xF235
Min.:
0
Unit:
Max.: 1 Data type: UInt16
Default:
0
Change:
At stop
Value Range:
0: Disabled
1: Enabled
Description
F2-54
Power limit during generating
Address:
0xF236
Min.:
0
Unit:
%
Max.: 200 Data type: UInt16
Default:
20
Change:
At stop
Value Range:
0.0% to 200.0%
Description
F2-55
Flux closed loop and torque linearity optimization in FVC mode
Address:
0xF237
Min.:
0
Unit:
Max.: 1111 Data type: UInt16
Default:
10
Change:
At stop
Value Range: