Parameter Groups
132
Description
F2-48
Speed loop bandwidth during inertia auto-tuning
Address:
0xF230
Min.:
0.1
Unit:
Hz
Max.: 100 Data type: UInt16
Default:
10
Change:
At stop
Value Range:
0.1 Hz to 100.0 Hz
Description
F2-49
Back EMF calculation
Address:
0xF231
Min.:
0
Unit:
Max.: 1 Data type: UInt16
Default:
0
Change: Unchangeable
Value Range:
0: Disabled
1: Enabled
Description
F2-50
Inertia auto-tuning mode
Address:
0xF232
Min.:
0
Unit:
Max.: 1 Data type: UInt16
Default:
0
Change:
At stop
Value Range:
0: Acceleration/Deceleration mode
1: Triangular wave mode
Description
F2-51
Inertia auto-tuning acceleration/deceleration coefficient
Address:
0xF233
Min.:
0.1
Unit:
Max.: 10 Data type: UInt16
Default:
1
Change:
At stop
Value Range:

Table of Contents