Parameter Groups
148
36: External stop terminal 1
37: Command source switchover terminal 2
38: PID integral pause
39: Switchover between main frequency source X and preset frequency
40: Switchover between auxiliary frequency source Y and preset frequency
41: Reserved
42: Position lock enabled
43: PID parameter switchover
44: User‑defined fault 1
45: User‑defined fault 2
46: Speed control/Torque control switchover
47: Emergency stop
48: External stop terminal 2
49: Deceleration DC braking
50: Clear the current running time
51: Two‑wire/Three‑wire control switchover
52: Electromagnetic shorting
53: Thickness overlaying
54: Roll diameter reset
55: Initial roll diameter 1
56: Initial roll diameter 2
57: Pre‑drive
58: Winding/Unwinding switchover
59: Roll diameter calculation disabled
60: Exit tension control
61: Terminal tension rise
62: Thickness selection 1
63: Thickness selection 2
90: Water cooling system fault
91: Low liquid level fault
92: Revolution count reset
93: Reserved
Description
0: No function
The DI terminal has no function.
1: Forward run
The operation mode of the AC drive is forward run. FWD indicates forward run. In
two‑wire mode 1 (F4‑11 = 0), activating the terminal sets the AC drive to forward
run. In two‑wire mode 2 (F4‑11 = 1), activating the terminal gives a running
command.