Parameter Groups
‑176‑
Default:
10
Change: In real time
Value Range:
F4‑13 to 10.00 V
Description
F4‑15 corresponds to the x axis of AI curve 1 maximum input, that is, the
maximum analog input voltage or current.
F4-16
Percentage corresponding to AI curve 1 maximum input
Address:
0xF410
Min.:
‑100
Unit:
%
Max.: 100 Data type: Int16
Default:
100
Change: In real time
Value Range:
‑100.0% to +100.0%
Description
F4‑16 corresponds to the y axis of the AI curve 1 maximum input, that is, the set
value corresponding to the maximum analog input.
F4-17
AI1 fitter time
Address:
0xF411
Min.:
0
Unit:
s
Max.: 10 Data type: UInt16
Default:
0.1
Change: In real time
Value Range:
0.00s to 10.00s
Description
Indicates the software filter time of AI1.
The longer the AI filter time, the stronger the anti‑interference ability and the
slower the response speed to the analog detection. The shorter the AI filter time,
the weaker the anti‑interference ability and the faster the response speed to
analog detection.
When the field analog signal is easy to be interfered, the stability of the analog
signal can be enhanced by increasing the AI filtering time.
F4-18
AI curve 2 minimum input
Address:
0xF412
Min.:
‑10
Unit:
V
Max.: F4‑20 Data type: Int16
Default:
‑10
Change: In real time
Value Range:
‑10.00 V to F4‑20