Parameter Groups
‑197‑
16: AI1 > AI2
17: Frequency upper limit reached
18: Frequency lower limit reached (operation related)
19: Undervoltage status output
20: Communication setting
21: Reserved
22: Reserved
23: Zero‑speed running 2 (at stop)
24: Accumulative power‑on time reached
25: Frequency‑level detection FDT2 output
26: Frequency 1 reach output
27: Frequency 2 reach output
28: Current 1 reach output
29: Current 2 reach output
30: Timing reach output
31: AI1 input limit exceeded
32: AC drive output load loss
33: Reverse running
34: Zero current status
35: Module temperature reached
36: Output current limit exceeded
37: Frequency lower limit reached (having output at stop)
38: Alarm output (direct output at fault or alarm)
39: Current over‑temperature pre‑warning
40: Current running time reached
41: Fault output 2
42: Fault output 3
Description
Used to set the function of DO2 on the expansion card.
The setting is similar to that of F5‑01.
F5-06
FMP output function selection
Address:
0xF506
Min.:
0
Unit:
‑
Max.: 22 Data type: UInt16
Default:
0
Change: In real time
Value Range: