Parameter Groups
206
Min.:
0
Unit:
s
Max.: 3600 Data type: UInt16
Default:
0
Change: In real time
Value Range:
0.0s to 3600.0s
Description
This parameter indicates the output delay of relay 1 on the control board. F5‑02
outputs an active signal after the set delay.
F5-19
Control board relay 2 output delay
Address:
0xF513
Min.:
0
Unit:
s
Max.: 3600 Data type: UInt16
Default:
0
Change: In real time
Value Range:
0.0s to 3600.0s
Description
This parameter indicates the output delay of relay 2 on the control board. F5‑03
outputs an active signal after the set delay.
F5-20
DO1 output delay
Address:
0xF514
Min.:
0
Unit:
s
Max.: 3600 Data type: UInt16
Default:
0
Change: In real time
Value Range:
0.0s to 3600.0s
Description
This parameter indicates the delay of DO1 output. F5‑04 outputs an active signal
after the set delay.
F5-21
Expansion card DO2 output delay
Address:
0xF515
Min.:
0
Unit:
s
Max.: 3600 Data type: UInt16
Default:
0
Change: In real time
Value Range:
0.0s to 3600.0s
Description
This parameter indicates the expansion card DO2 output delay. F5‑05 outputs an
active signal after the set delay.