Parameter Groups
216
Min.:
0
Unit:
Max.: 360 Data type: UInt16
Default:
0
Change:
At stop
Value Range:
0360
Description
F6-33
Proportion of synchronous motor speed tracking
Address:
0xF621
Min.:
0.1
Unit:
Max.: 10 Data type: UInt16
Default:
1
Change:
At stop
Value Range:
0.110.0
Description
F6-34
Integral of synchronous motor speed tracking
Address:
0xF622
Min.:
0.1
Unit:
Max.: 10 Data type: UInt16
Default:
1
Change:
At stop
Value Range:
0.110.0
Description
F6-35
Maximum current limit for DC braking
Address:
0xF623
Min.:
80
Unit:
%
Max.: 135 Data type: UInt16
Default:
80
Change:
At stop
Value Range:
80% to 135%
Description
The base value is the rated current of the AC drive. The DC braking current set by
F6‑05 and F6‑13 is restricted by this parameter.
F6-36
Speed loop feedforward
Address:
0xF624