Parameter Groups
‑218‑
3: Forward jog
The MF.K key is used for enabling forward jog (FJOG). This function is valid only
when the operating panel is set as the command source.
4: Reverse jog
The MF.K key is used for enabling reverse jog (RJOG). This function is available
only when the operating panel is set as the command source.
F7-02
STOP/RES key function
Address:
0xF702
Min.:
0
Unit:
‑
Max.: 1 Data type: UInt16
Default:
0
Change: In real time
Value Range:
0: STOP/RESET key enabled only in operating panel control mode
1: STOP/RESET key enabled in any operating mode
Description
The STOP/RESET key on the operating panel is used for stop/reset. This
parameter is used for setting the function of this key.
0: STOP/RESET key enabled only in operating panel control mode
The STOP/RESET key is valid only in operating panel control mode.
1: STOP/RESET key enabled in any operating mode
The STOP/RESET key is valid in any operating mode.
F7-03
LED running display parameter 1
Address:
0xF703
Min.:
0
Unit:
‑
Max.: 0xFFFF Data type: UInt16
Default:
0x1F
Change: In real time
Value Range: