Parameter Groups
ā225ā
F8-05
Acceleration time 3
Address:
0xF805
Min.:
0
Unit:
s
Max.: 6500 Data type: UInt16
Default:
20
Change: In real time
Value Range:
0.0s to 6500.0s
Description
The AC drive provides four groups of acceleration time, which can be switched by
using the DI. This parameter defines the third group of acceleration time.
F8-06
Deceleration time 3
Address:
0xF806
Min.:
0
Unit:
s
Max.: 6500 Data type: UInt16
Default:
20
Change: In real time
Value Range:
0.0s to 6500.0s
Description
The AC drive provides four groups of deceleration time, which can be switched by
using the DI. This parameter defines the third group of deceleration time.
F8-07
Acceleration time 4
Address:
0xF807
Min.:
0
Unit:
s
Max.: 6500 Data type: UInt16
Default:
20
Change: In real time
Value Range:
0.0s to 6500.0s
Description
The AC drive provides four groups of acceleration time, which can be switched by
using the DI. This parameter defines the fourth group of acceleration time.
F8-08
Deceleration time 4
Address:
0xF808
Min.:
0
Unit:
s
Max.: 6500 Data type: UInt16
Default:
20
Change: In real time
Value Range:
0.0s to 6500.0s