Parameter Groups
‑365‑
Description
A9-01
Auto-tuning of rotor resistance gain for asynchronous motors in FVC mode
Address:
0xA901
Min.:
0
Unit:
Max.: 100 Data type: UInt16
Default:
5
Change: In real time
Value Range:
0100
Description
A9-02
Start frequency auto-tuning of the rotor resistance for asynchronous motors
in FVC mode
Address:
0xA902
Min.:
2
Unit:
Hz
Max.: 100 Data type: UInt16
Default:
7
Change: In real time
Value Range:
2 Hz to 100 Hz
Description
A9-03
Observed magnetic field coefficient of asynchronous motors in FVC mode
Address:
0xA903
Min.:
30
Unit:
Max.: 150 Data type: UInt16
Default:
40
Change: In real time
Value Range:
30 to 150
Description
A9-04
Maximum torque limit coefficient in the field-weakening range for
asynchronous motors
Address:
0xA904
Min.: 30 Unit:
Max.: 150 Data type: UInt16
Default:
80
Change: In real time
Value Range: