Parameter Groups
‑369‑
A9-18
Initial position angle detection of synchronous motor
Address:
0xA912
Min.:
0
Unit:
Max.: 2 Data type: UInt16
Default:
0
Change: In real time
Value Range:
0: Detected upon running
1: Not detected
2: Detected upon initial running after power‑on
Description
A9-20
Flux weakening mode
Address:
0xA914
Min.:
0
Unit:
Max.: 3 Data type: UInt16
Default:
1
Change:
At stop
Value Range:
0: Automatic mode
1: Synchronous motor adjustment mode
2: Synchronous motor hybrid mode
3: Disabled
Description
A9-21
Flux weakening gain of synchronous motor
Address:
0xA915
Min.:
0
Unit:
Max.: 50 Data type: UInt16
Default:
5
Change: In real time
Value Range:
050
Description
A9-22
Upper limit margin of synchronous motor output voltage
Address:
0xA916
Min.:
0
Unit:
%
Max.: 50 Data type: UInt16
Default:
5
Change: In real time
Value Range:
0% to 50%