Parameter Groups
‑370‑
Description
A9-23
Maximum force adjustment gain of synchronous motor
Address:
0xA917
Min.:
20
Unit:
%
Max.: 300 Data type: UInt16
Default:
100
Change: In real time
Value Range:
20% to 300%
Description
A9-24
Exciting current adjustment gain calculated by synchronous motor
Address:
0xA918
Min.:
40
Unit:
%
Max.: 200 Data type: UInt16
Default:
100
Change: In real time
Value Range:
40% to 200%
Description
A9-25
Estimated speed integral gain of synchronous motor in SVC mode
Address:
0xA919
Min.:
5
Unit:
%
Max.: 1000 Data type: UInt16
Default:
30
Change: In real time
Value Range:
5% to 1000%
Description
A9-26
Estimated speed proportional gain of synchronous motor in SVC mode
Address:
0xA91A
Min.:
5
Unit:
%
Max.: 300 Data type: UInt16
Default:
20
Change: In real time
Value Range: