EasyManua.ls Logo

Inovance MD500-PLUS Series - Page 411

Inovance MD500-PLUS Series
718 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Parameter Groups
410
Default:
0
Change: In real time
Value Range:
0.0 m/min to 500.0 m/min
Description
When B0‑02 is set to 0, at zero material speed, the unwinding reel has no output
and the material is not tightened. When B0‑02 is set to a value between 0.1 m/min
to 500.0 m/min, under no‑load conditions or if the material is in loose state, the
unwinding reel runs at the set linear speed in the reverse direction; at zero
material speed, the unwinding real maintains output and the material is
tightened.
B0-03
Mechanical transmission ratio
Address:
0xB003
Min.:
0.01
Unit:
Max.: 300 Data type: UInt16
Default:
1
Change: In real time
Value Range:
0.01 to 300.00
Description
This parameter specifies the ratio of motor speed to reel speed. Set B0‑03 based
on the mechanical transmission structure. When the roll diameter is calculated
based on linear speed (B0‑07 is set to 0), a larger value of B0‑03 means a larger
roll diameter, and vice versa. According to this rule, the parameter can be
corrected according to the deviation between the calculated roll diameter and the
actual value.
B0-04
Linear speed input source
Address:
0xB004
Min.:
0
Unit:
Max.: 6 Data type: UInt16
Default:
0
Change:
At stop
Value Range:
0: No input
1: AI1
2: AI2
3: AI3
4: Pulse input (DI5)
5: Communication setting (1000H)
6: Communication setting (731AH)

Table of Contents

Other manuals for Inovance MD500-PLUS Series