Parameter List
‑43‑
Parame
ter
Address Name Value Range Default Unit Change
Method
Page
F9‑50 0xF932 Fault protection
action selection 3
Ones (position): Reserved
0: Coast to stop
Tens (position): Value of E63
0: Coast to stop
1: Decelerate to stop
4: Warning
5: Canceled
Hundreds (position): Value of
E23
0: Coast to stop
5: Canceled
5040 At stop "
F9‑50
"
on
page 257
Contin
ued
Contin
ued
Continued Thousands (position): Value of
E24
0: Coast to stop
5: Canceled
Ten thousands (position):
Value of E25
0: Coast to stop
1: Decelerate to stop
4: Warning
5: Canceled
Contin
ued
Contin
ued
Continued Continued
F9‑51 0xF933 Fault protection
action selection 4
Ones (position): Value of E26
0: Coast to stop
1: Decelerate to stop
4: Warning
5: Canceled
Tens position: Value of E27
0: Coast to stop
1: Decelerate to stop
3: Electromagnetic shorting
4: Warning
5: Canceled
51111 At stop "
F9‑51
"
on
page 257