Inovance MD500-PLUS Series - B6 Communication Free Mapping Configuration Parameters

Inovance MD500-PLUS Series
718 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Parameter Groups
440
Max.: 100 Data type: UInt16
Default:
70
Change: In real time
Value Range:
0.0% to 100.0%
Description
Taper 4 set by multi‑point linear taper curve
B2-17
Linear taper switchover point 5
Address:
0xB211
Min.:
B2‑15
Unit:
mm
Max.: B0‑08 Data type: UInt16
Default:
400
Change: In real time
Value Range:
B2‑15 to B0‑08
Description
Winding diameter 5 set by multi‑point linear taper curve
B2-18
Taper of switchover point 5
Address:
0xB212
Min.:
0
Unit:
%
Max.: 100 Data type: UInt16
Default:
50
Change: In real time
Value Range:
0.0% to 100.0%
Description
Taper 5 set by multi‑point linear taper curve
B2-19
Taper at maximum roll diameter
Address:
0xB213
Min.:
0
Unit:
Max.: 100 Data type: UInt16
Default:
30
Change: In real time
Value Range:
0.0100.0
Description
Taper corresponding to the maximum roll diameter.