Function Application
‑659‑
Para. Name
Value Range
Description
F7‑05 LED stop
display
parame
ter
BIT00: Frequency reference
(Hz)
BIT01: Bus voltage (V)
BIT02: DI state
BIT03: DO state
BIT04: AI1 voltage (V)
BIT05: AI2 voltage (V)
If a parameter needs to be
displayed when the AC drive stops,
set its corresponding bit to 1. After
converting this binary number to a
hexadecimal number, set it in F7‑
05.
Continued
Contin
ued
BIT06: AI3 voltage (V)
BIT07: Count value
BIT08: Length value
BIT09: PLC stage
BIT10: Load speed display
BIT11: PID setting
BIT12: Pulse input
frequency (kHz)
BIT14: Roll diameter (mm)
BIT15: Tension reference
after taper setting (N)
Continued
The following table lists monitoring parameters, which can be monitored on the
operating panel or in the background in real time.
Table 3–43 Monitoring parameters
Para. Name
Minimum Unit Description
U1‑00
Linear speed 0.1m/min
U1‑01
Current roll diameter
0.1 mm
U1‑02
Linear speed
synchronous
frequency
0.01 Hz
U1‑03 PID output
frequency
0.01 Hz
U1‑04
Current tension
reference
1 N
U1‑05
Tension reference
after taper
1 N
U1‑06
Open‑loop torque
0.1%
U1‑07 PID output torque 0.1%