Function Application
680
Para.
Function Basic Unit Description
U0‑07 DI state 1
This parameter indicates the current state of
the DI. Each bit of the binary number
converted from this value corresponds to one
DI signal. The value 1 indicates that the input
is high level. The value 0 indicates that the
input is low level. Each bit corresponds to an
input terminal in the following pattern.
U0‑08 DO state 1
This parameter indicates the current state of
the DO. Each bit of the binary number
converted from this value corresponds to one
DO signal. The value 1 indicates that the
output is high level. The value 0 indicates that
the output is low level. Each bit corresponds
to an output terminal in the following pattern.
U0‑09
AI1 voltage (V)
0.01 V
U0‑10
AI2 voltage (V)
0.01 V/0.01
mA