Function Application
‑682‑
Para.
Function Basic Unit Description
U0‑27
Pulse input
reference (Hz)
1 Hz
This parameter indicates the DI5 high‑speed
pulse sampling frequency. It is the same as
U0‑18, except for difference in units.
U0‑28
Communication
0.01%
This parameter indicates the data written by
the communication address 0x1000. The base
value of the percentage is determined by the
value of communication address 0x1000.
U0‑29
Encoder
feedback speed
(Hz)
0.01 Hz
This parameter indicates the motor running
frequency measured by the encoder.
U0‑30
Display of main
frequency X
0.01 Hz
This parameter indicates the main frequency
reference.
U0‑31
Display of
auxiliary
frequency Y
0.01 Hz
This parameter indicates the auxiliary
frequency reference.
U0‑32 Any memory
address
1
‑
U0‑33
Synchronous
motor rotor
position
0.1
‑
U0‑34 Motor
temperature
1℃
This parameter indicates the motor
temperature sampled through AI3.
For details about motor temperature
measurement, see the description of F9‑56
(type of motor temperature sensor).
U0‑35 Target torque
(%)
0.10%
This parameter indicates the current torque
upper limit reference, which is a percentage of
the rated motor torque.
U0‑36
Resolver
position
1
‑
U0‑37
Power factor
angle
0.1º This parameter indicates the current power
factor angle.