EasyManua.ls Logo

Inovance MD500-PLUS Series - 4.1.5 Group Fd: Communication Parameters

Inovance MD500-PLUS Series
718 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Communication
‑703‑
AO1 control (write‑only)
Command Address Command Content
2002H
0 to 7FFF indicates 0% to 100%.
AO2 control (write‑only)
Command Address Command Content
2003H
0 to 7FFF indicates 0% to 100%.
Pulse output control (write‑only)
Command Address Command Content
2004H
0 to 7FFF indicates 0% to 100%.
AC drive fault description
AC Drive Fault
Address
AC Drive Fault Information
8000H
0000: No fault
0001: Reserved
0002: Overcurrent during
acceleration
0003: Overcurrent during
deceleration
0004: Overcurrent during
operation at constant speed
0005: Overvoltage during
acceleration
0006: Overvoltage during
deceleration
0007: Overvoltage during
operation at constant speed
0008: Snubber resistor overload
0009: Undervoltage fault
000A: AC drive overload
000B: Motor overload
000C: Input phase loss
000D: Output phase loss
000E: IGBT overtemperature
000F: External fault
0010: Communication fault
0011: Contactor fault
0012: Current detection fault
0013: Motor auto‑tuning fault
0014: Encoder/PG card fault
0015: Parameter read‑write error
0016: AC drive hardware fault
0017: Motor short circuit to
ground
0018: Reserved
0019: Reserved
001A: Running time reach
001B: User‑defined fault 1
001C: User‑defined fault 2
001D: Power‑on time reach
001E: Load lost
001F: PID feedback loss during
operation
0028: Fast current limit timeout
0029: Motor switchover fault
during operation
002A: Excessive speed deviation
002B: Motor overspeed
002D: Motor overtemperature
005A: Encoder PPR reference error
005B: Encoder not connected
005C: Initial position error
005E: Speed feedback error

Table of Contents

Other manuals for Inovance MD500-PLUS Series

Related product manuals