Page #170 background image
Appendix C: BMC Sensor Tables Inte Server Board S2600CW Family TPS
156
Revision 2.4
Full Sensor Name
(Sensor name in SDR)
Senso
r #
Platform
Applicabili
ty
Sensor Type Event/Rea
ding Type
Event Offset
Triggers
Contrib. To
System
Status
Assert
/De-
assert
Readab
le
Value/
Offsets
Event
Data
Rearm Stand-
by
06 Redundant:
degraded from fully
redundant state.
Degraded
07 Redundant:
Transition from non-
redundant state.
Degraded
IPMI Watchdog
(IPMI Watchdog)
03h All
Watchdog 2
23h
Sensor
Specific
6Fh
00 - Timer expired,
status only
OK As Trig Offset A X
01 - Hard reset
02 - Power down
03 - Power cycle
08 - Timer interrupt
Physical Security
(Physical Scrty)
04h
Chassis
Intrusion is
chassis-
specific
Physical
Security
05h
Sensor
Specific
6Fh
00 - Chassis intrusion
Degraded
OK
As
and
De
Trig Offset A X
04 - LAN leash lost
FP Interrupt
(FP NMI Diag Int)
05h
Chassis -
specific
Critical
Interrupt
13h
Sensor
Specific
6Fh
00 - Front panel
NMI/diagnostic
interrupt
OK As Trig Offset A
QPI Correctable Event
(QPI Corr Sensor)
06h All
Critical Event
13h
72h
QPI Uncorrectable Event
(QPI Fatl Sensor)
07h All
Critical Event
13h
73h
SMI Timeout
(SMI Timeout)
06h All
SMI Timeout
F3h
Digital
Discrete
03h
01 State asserted Fatal
As
and
De
Trig Offset A
System Event Log
(System Event Log)
07h All
Event Logging
Disabled
10h
Sensor
Specific
6Fh
02 - Log area
reset/cleared
OK As Trig Offset A X

Table of Contents

Other manuals for Intel S2600CW

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Intel S2600CW and is the answer not in the manual?

Intel S2600CW Specifications

General IconGeneral
BrandIntel
ModelS2600CW
CategoryServer Board
LanguageEnglish

Related product manuals