Intel® Server Board S2600CW Family TPS Appendix C: BMC Sensor Tables
Revision 2.4
157
Full Sensor Name
(Sensor name in SDR)
Senso
r #
Platform
Applicabili
ty
Sensor Type Event/Rea
ding Type
Event Offset
Triggers
Contrib. To
System
Status
Assert
/De-
assert
Readab
le
Value/
Offsets
Event
Data
Rearm Stand-
by
System Event
(System Event)
08h All
System Event
12h
Sensor
Specific
6Fh
04 PEF action OK As - Trig Offset A X
Button Sensor
(Button)
09h All
Button/Switch
14h
Sensor
Specific
6Fh
00 Power Button
02 Reset Button
OK AS _ Trig Offset A X
BMC Watchdog 0Ah All
Mgmt System
Health
28h
Digital
Discrete
03h
01 State Asserted Degraded As Trig Offset A -
Voltage Regulator Watchdog
(VR Watchdog)
0Bh All
Voltage
02h
Digital
Discrete
03h
01 State Asserted Fatal
As
and
De
Trig Offset M X
Fan Redundancy
1
(Fan Redundancy)
0Ch
Chassis-
specific
Fan
04h
Generic
0Bh
00 - Fully redundant
OK
As
and
De
Trig Offset A
01 - Redundancy lost
Degraded
02 - Redundancy
degraded
Degraded
03 - Non-redundant:
Sufficient resources.
Transition from
redundant
Degraded
04 - Non-redundant:
Sufficient resources.
Transition from
insufficient.
Degraded
05 - Non-redundant:
insufficient resources.
Non-Fatal

Table of Contents

Other manuals for Intel S2600CW

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Intel S2600CW and is the answer not in the manual?

Intel S2600CW Specifications

General IconGeneral
BrandIntel
ModelS2600CW
CategoryServer Board
LanguageEnglish

Related product manuals