8.
Select the FACTORY_IMAGE partition and click Edit.
9.
In the Edit Partition dialog box, select your factory image .sof file in the Input
file drop-down list and click OK.
Note: You must assign Page 0 to Factory Image. Intel recommends that you let
the Intel Quartus Prime software assign the Start address of the
FACTORY_IMAGE automatically by retaining the default value for Address
Mode which is Auto. From the Address Mode drop down list, select Block
to set an End address value for the FACTORY_IMAGE. The Programming
File Generator reserves and assigns the start and end flash addresses to
store BOOT_INFO, SPT0, SPT1, CPB0, and CPB1.
10. Select the flash memory and click Add Partition.
11.
In the Add Partition dialog box, select for application image .sof file from the
Input file drop-down list, assign the page number.
12. Repeat this step for additional application images and click OK. You can add up to
three partitions for three application images. The page 1 application image is the
highest priority, and the page 3 image is the lowest priority.
13.
For .jic files,
Click Select at the Flash loader, select your device family and device name, and
click OK.
14. Click Generate to generate the remote system upgrade programming files. After
generating the programming file, you can proceed to program the flash memory.
Note:
The generated .jic file contains only the initial flash data. If a remote host
updates the initial flash image and then the application performs a verify
operation, the verify operation fails. You can use the programmer to
examine the flash content and compare it to the new flash image .rpd.
Note: If you plan to update the factory image, Intel recommends reserving an
additional 64 KB space for possible expansion of the factory image.
Complete the following steps to reserve extra space for updates to the
factory image:
a.
Identify the new end address by adding 64 KB to the existing END ADDRESS
of the FACTORY_IMAGE. The end address is available in the .map file. For
example, if the current end address is 0x00423FF, the new end address is
0x00433FF.
b.
Repeat the steps to regenerate the new .jic file. On the Configuration
Device tab, select the FACTORY_IMAGE partition and click Edit. In the Edit
Partition dialog box, under the Address Mode drop down list, select Block
to set the new End address value for the FACTORY_IMAGE.
5.5.2. Generating a Single RSU Image
Follow these steps to generate single RSU image (.rpd) for adding or updating
application image in user mode:
1. On the File menu, click Programming File Generator.
2. Select Stratix 10 from the Device family drop-down list.
3. Select the configuration mode from the Configuration mode drop-down list. The
current Intel Quartus Prime only supports remote system upgrade feature in
Active Serial x4.
5. Remote System Upgrade
UG-S10CONFIG | 2018.11.02
Send Feedback
Intel Stratix 10 Configuration User Guide
85