EasyManuals Logo

INVT Goodrive300-01A-RT Series User Manual

INVT Goodrive300-01A-RT Series
162 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #55 background imageLoading...
Page #55 background image
Goodrive300-01A-RT series integrated machine Function description
-49-
Function
code
Name
Description
Default
Modify
19: Current detection fault (ItE)
20: Motor autotuning fault (tE)
21: EEPROM operation fault (EEP)
22: PID feedback offline fault (PIDE)
23: Reserved
24: Running time reached (END)
25: Electronic overload (OL3)
26: Panel communication error (PCE)
27: Parameter upload error (UPE)
28: Parameter download error (DNE)
2931: Reserved
32: To-ground short circuit fault 1 (ETH1)
33: To-ground short circuit fault 2 (ETH2)
34: Speed deviation fault (dEu)
35: Mal-adjustment fault (STo)
36: Underload fault (LL)
37: Reserved
38: Phase sequence fault (PSF)
39: 3PH current imbalance of the fan (SPOF)
40: Fan overload (OLF)
41: Solenoid valve overcurrent (TOC)
P07.33
Running frequency at
present fault
0.00
P07.34
Ramp reference
frequency at present
fault
0.00
P07.35
Output voltage at
present fault
0
P07.36
Output current at
present fault
0.0
P07.37
Bus voltage at present
fault
0.0
P07.38
Max. temperature at
present fault
0.0
P07.39
Input terminal status at
present fault
0
P07.40
Output terminal status
at present fault
0

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the INVT Goodrive300-01A-RT Series and is the answer not in the manual?

INVT Goodrive300-01A-RT Series Specifications

General IconGeneral
BrandINVT
ModelGoodrive300-01A-RT Series
CategoryInverter
LanguageEnglish

Related product manuals