Goodrive300-01A-RT series integrated machine Function description
-52-
Function
code
Name
Description
Default
Modify
P08.18
Automatic restart delay
0.06000.0s
60.0s
P08.19
Low-voltage frequency
limit running time
0.06000.0s
60.0s
P08.24
Fan protection
0x000x11
LED ones:
0: Disable the fan 3PH current imbalance
protection
1: Enable the fan 3PH current imbalance
protection
LED tens:
0: Disable the fan overload protection
1: Enable the fan overload protection
0x11
P08.25
Keypad lock enable
0: Do not lock keypad
1: Allow to lock keypad
Lock: Press PRG key+ DATA key
simultaneously
Unlock: Keep DATA key pressed down and
then click V key by three times.
0
P08.26
Maintenance timing
mode
0: No timing during sleep
1: Timing during sleep
0
P08.27
Optimization mode
0x000x11
LED ones: SM inductance optimization
0: Disable
It is applicable to the surface-mounted
synchronous motors. P02.21 (Direct-axis
inductance of SM 1) and P02.22
(Quadrature-axis inductance of SM 1) are
used in the calculation.
1: Enable
It is applicable to the embedded/
surface-mounted synchronous motors.
P02.21 (Direct-axis inductance of SM 1) is
used in the calculation.
Note: You can disable or enable the
optimization mode according to the motor at
the scene.
LED tens: Bus voltage detection optimization
0: Disable
01