Goodrive300-01A-RT series integrated machine Function description
-76-
Function
code
Name
Description
Default
Modify
restart delay state and restart count-down to
prevent immediate restart. After restart
delay time is up, the system enters standby
state. Under standby state, start command
can be received.
Setting range: 03600s
P19.19
Output value of
temperature PID
Display the output value of temperature PID
regulation of machine head, 100%
corresponds to max. output frequency
(P00.03) of the fan.
Setting range: 0.00100.00%
0.00%
P19.21
Present auxiliary
temperature
Display the auxiliary temperature value
detected at present.
P18.28
0
150
P17.20
-20
PT1 input
voltage
Present auxiliary temperature
P19.21
P18.29
P18.32
0
150
P17.22
-20
PT2 input
voltage
Present auxiliary temperature
P19.21
P18.33
P18.03=0
P18.03=1
20
120
20
120
Range: -20150
0
P19.22
Input power phase
sequence state
0: Positive sequence
1: Negative sequence
2: Phase loss
0
P19.23
RST input power
voltage