SECTION 8 - MICROPANEL
12/10/2008
ENG ASCII Operational Code ENG ASCII Fault Code ENG ASCII Fault Code (cont.)
PAGE PAGE PAGE PAG E PAGE PAGE
P56,58 P54,56 C_OPER.CODE P57,59 P55,57 C_FAULT.CODE P57,59 P55,57 C_FAULT.CODE
63 63 Manual Override 1 1 Low Ambient Temperature 52 53 SPARE
64 64 Daily Schedule Shutdown 2 2 High Ambient Temperature 53 54 SPARE
65 65 Unit Switch OFF 3 3 Low Chilled Liquid Temperature 54 55 SPARE
66 66 Remote Controlled Shutdown 4 4 SPARE0 55 56 SPARE
67 67 Loss of External Communications 5 5 Low RTC Battery Voltage 56 57 SPARE
68 68 Flow Switch Shutdown 6 6 Invalid Number of Comp ressors Selected 57 58 SPARE
69 69 VSD Cooling Shutdown 7 7 VSD Communications Failure 58 59 SPARE
70 70 SPARE 8 8 Pre-charge Low DC Bus Voltage 59 60 SPARE
71 71 SPARE 9 9 Pre-charge DC Bus Voltage Imbalance 60 61 SPARE
72 72 SPARE 10 10 Bus Voltage High DC 61 62 SPARE
73 73 SPARE 11 11 Bus Voltage Low DC 62 62 SPARE
74 74 No Run Permissive 12 12 Voltage Imbalance DC Bus
75 75 Anti-Recycle Timer Active 13 13 High VSD Ambient Temperature
76 76 System Switch OFF 14 14 Phase Input Single
77 77 System Not Running 15 15 VSD Power Supply Fault
78 78 System Running 16 16 VSD Logic Board Fault
79 79 Discharge Pressure Limiting 17 17 Motor Current Overload (Hardware)
80 80 Suction Pressure Limiting 18 18 CT Plug Fault
81 81 Motor Current Limiting 19 19 SPARE
82 82 Motor Temperature Limiting 20 20 SPARE
83 83 ISN Motor Current Limiting 21 21 SPARE
84 84 Remote Motor Current Limiting 22 22 SPARE
85 85 System Pumping Down 23 23 SPARE
86 86 VSD PreCharging 24 24 SPARE
87 87 VSD Baseplate Temp Limiting 25 25 SPARE
88 88 VSD Internal Ambient Temp Limiting 26 26 SPARE
89 89 Sound Limiting 27 27 High Discharge Pressure (Software)
90 90 ISN Sound Limiting 28 28 High Differential Oil Pressure
91 91 Remote Sound Limiting 29 29 Low Differential Oil Pressure
92 92 Pulldown Motor Current Limiting 30 30 Low Suction Pressure
93 93 SPARE 31 31 High Discharge Temperature
94 94 SPARE 32 32 High Oil Temperature
95 95 SPARE 33 33 Low Suction Superheat
96 96 SPARE 34 34 Sensor Failure
35 35 Low Motor Current
36 36 High Motor Temperature
37 37 Pre-charge Low DC Bus Voltage
38 38 Pre-charge DC Bus Voltage Imbalance
39 39 High DC Bus Voltage
40 40 Low DC Bus Voltage
41 41 DC Bus Voltage Imbalance
42 42 High Motor Current
43 43 Motor Current Overload (Software)
44 44 IGBT Gate Driver Fault
45 45 High Baseplate Temperature
46 46 Single Phase Input
47 47 VSD Run Signal Fault
48 48 High Discharge Press (Hardware – HPCO)
49 49 High Flash Tank Level
50 50 Control Voltage Fault
51 51 Low Discharge Superheat
Revision: YCAV_YCIV Latitude (Rev J_04).xls Tab: YCAV_YCIV (1 & 2 Comps) Property of Johnson Controls, York, PA Page: 3
TABLE 29 - YORKTALK 2 COMMUNICATIONS DATA MAP (CONT’D)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Johnson Controls York YCIV A Series and is the answer not in the manual?

Johnson Controls York YCIV A Series Specifications

General IconGeneral
BrandJohnson Controls
ModelYork YCIV A Series
CategoryChiller
LanguageEnglish

Related product manuals