Check the red and yellow alarm LEDs on the craft interface. Power supply failure or removal triggers an
alarm that causes one or both of the LEDs to light. You can display the associated error messages by
issuing the following command:
user@host> show chassis alarms
Periodically inspect the site to ensure that the grounding and power cables connected to the router are
securely in place and that there is no moisture accumulating near the router.
CAUTION: Do not mix AC and DC power supplies in the same chassis.
SEE ALSO
MX10003 AC Power System Description | 35
MX10003 AC Power Supply Module LEDs | 36
Replacing an MX10003 AC Power Supply
IN THIS SECTION
Removing an MX10003 AC Power Supply | 127
Installing an MX10003 AC Power Supply | 129
Removing an MX10003 AC Power Supply
Before you remove a power supply, be aware of the following:
NOTE: The minimum required number of power supplies must be present in the router at all
times.