Table 22: Router Environmental Specifications
ValueDescription
No performance degradation up to 10,000 ft (3048 m)Altitude
Normal operation ensured in relative humidity range of 5%
through 90%, noncondensing
Relative humidity
Normal operation ensured in temperature range of 32°F (0°C)
through 104°F (40°C)
Nonoperating storage temperature in shipping container:
–40°F (–40°C) through 158°F (70°C)
Temperature
Designed to meet Telcordia Technologies Zone 4 earthquake
requirements
Seismic
1705 BTU/hourMaximum thermal output
(500 W)
NOTE: Install the router only in restricted areas, such as dedicated equipment rooms and
equipment closets, in accordance with Articles 110-16, 110-17, and 110-18 of the National
Electrical Code, ANSI/NFPA 70.
SEE ALSO
Routine Maintenance Procedures for MX10003 Routers | 116
General Safety Guidelines for Juniper Networks Devices
General Safety Warnings for Juniper Networks Devices | 178
MX10003 Router Grounding Specifications
Grounding Points Specifications
To meet safety and electromagnetic interference (EMI) requirements and to ensure proper operation, the
router must be adequately grounded before power is connected. To ground AC-powered and DC-powered
61

Table of Contents

Other manuals for Juniper MX10003

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Juniper MX10003 and is the answer not in the manual?

Juniper MX10003 Specifications

General IconGeneral
ModelMX10003
CategoryNetwork Router
Routing EngineRE-MX10003
Throughput2.4 Tbps
Operating SystemJunos OS
Power SupplyAC or DC
Rack Units/Form Factor3 U
RedundancyPower supplies, fans
Slot Count3

Related product manuals