EasyManua.ls Logo

Juniper MX10003 - Maintaining the Routing and Control Board (RCB)

Juniper MX10003
230 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Maintaining the Routing and Control Board (RCB)
Purpose
For optimum router performance, verify the condition of the RCB on regular basis.
Action
On a regular basis:
Check the LEDs on the front panel to view information about the status of the RCB.
To check the status of the Routing Engine on the RCB, issue the show chassis routing-engine command.
The output is similar to the following:
user@host> show chassis routing-engine
Routing Engine status:
Slot 0:
Current state Master
Election priority Master (default)
Temperature 44 degrees C / 111 degrees F
CPU temperature 41 degrees C / 105 degrees F
DRAM 49110 MB (49152 MB installed)
Memory utilization 4 percent
5 sec CPU utilization:
User 0 percent
Background 0 percent
Kernel 1 percent
Interrupt 0 percent
Idle 99 percent
1 min CPU utilization:
User 0 percent
Background 0 percent
Kernel 1 percent
Interrupt 0 percent
Idle 99 percent
5 min CPU utilization:
User 0 percent
Background 0 percent
Kernel 1 percent
Interrupt 0 percent
Idle 99 percent
15 min CPU utilization:
User 0 percent
Background 0 percent
Kernel 1 percent
135