Replace an SFP, SFP+, or QSFP+ Transceiver | 157
Replace a QSFP28 Transceiver | 159
Maintaining MICs
Purpose
For optimum router performance, verify the condition of the MICs.
Action
On a regular basis:
•
Check the LEDs on MIC faceplates. The meaning of the LED states differs for various MICs. For more
information, see the MX Series Interface Module Reference. If the MPC that houses the MIC detects a
MIC failure, the MPC generates an alarm message to be sent to the Routing Engine.
•
Issue the show chassis fpc pic-status CLI command. The MIC slots in an MPC are numbered PIC 0 and
PIC 1, right to left:
user@host> show chassis fpc pic-status
Slot 0 Online LC2103
PIC 0 Online 6xQSFPP
PIC 1 Online MIC1
Slot 1 Online LC2103
PIC 0 Online 6xQSFPP
PIC 1 Online MIC1
For further description of the output from the command, see the CLI Explorer.