:STATe <b>
[:SENSe[1]]:CURRent:AC:REFerence:STATe <b> Control reference for ACI
[:SENSe[1]]:CURRent[:DC]:REFerence:STATe <b> Control reference for DCI
[:SENSe[1]]:VOLTage:AC:REFerence:STATe <b> Control reference for ACV
[:SENSe[1]]:VOLTage[:DC]:REFerence:STATe <b> Control reference for DCV
[:SENSe[1]]:RESistance:REFerence:STATe <b> Control reference for 2
[:SENSe[1]]:FRESistance:REFerence:STATe <b> Control reference for 4
[:SENSe[1]]:FREQuency:REFerence:STATe <b> Control reference for FREQ
[:SENSe[1]]:PERiod:REFerence:STATe <b> Control reference for PER
[:SENSe[1]]:TEMPerature:REFerence:STATe <b> Control reference for TEMP
Parameters <b> = 1 or ON Enable reference
0 or OFF Disable reference
Query :STATe? Query state of reference
Description These commands are used to enable or disable Reference for the specified
function. When enabled, the displayed reading will include the programmed
reference value (see :REFerence <n> and :ACQuire). When disabled, the
displayed reading will not include the reference value.
:ACQuire
[:SENSe[1]]:CURRent:AC:REFerence:ACQuire Acquire reference for ACI
[:SENSe[1]]:CURRent[:DC]:REFerence:ACQuire Acquire reference for DCI
[:SENSe[1]]:VOLTage:AC:REFerence:ACQuire Acquire reference for ACV
[:SENSe[1]]:VOLTage[:DC]:REFerence:ACQuire Acquire reference for DCV
[:SENSe[1]]:RESistance:REFerence:ACQuire Acquire reference for 2
[:SENSe[1]]:FRESistance:REFerence:ACQuire Acquire reference for 4
[:SENSe[1]]:PERiod:REFerence:ACQuire Acquire reference for PER
[:SENSe[1]]:FREQuency:REFerence:ACQuire Acquire reference for FREQ
[:SENSe[1]]:TEMPerature:REFerence:ACQuire Acquire reference for TEMP
Description When one of these commands is sent, the measured input signal is acquired
and established as the reference value. This command is typically used to
zero the display. For example, if the instrument is displaying a 1µV offset,
sending this command and enabling Reference (see :STATe) zeroes the dis-
play.
This command is functional only if the instrument is on the specified mea-
surement function. Sending this command while in any other function caus-
es an error. Also, if the latest reading is overflowed (“OFLO”) or a reading
has not been triggered (“----”), an error occurs when this command is sent.
The :ACQuire command is coupled to the :REFerence <n> command. See
the description for :REFerence for details.
5-44 SCPI Command Reference

Table of Contents

Other manuals for Keithley 2000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Keithley 2000 and is the answer not in the manual?

Keithley 2000 Specifications

General IconGeneral
Digits6.5
DC Voltage Range100 mV to 1000 V
AC Voltage Range100 mV to 750 V
Resistance Range100 Ω to 100 MΩ
ConnectivityIEEE-488 (GPIB)
Display TypeVFD

Related product manuals