EasyManuals Logo

Keysight Technologies J-BERT M8020A User Manual

Keysight Technologies J-BERT M8020A
502 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #157 background imageLoading...
Page #157 background image
Keysight M8070A Programming Guide 157
SCPI Command Reference 5
URce]:JITTer:HFRequency:PERiodic(*):FREQuency[?]
Syntax [:SOURce]:JITTer:HFRequency:PERiodic(*):FREQuency ‘identifier’, <NRf>
[:SOURce]:JITTer:HFRequency:PERiodic(*):FREQuency? ‘identifier’
Input
Parameters
‘identifier’: 'M*.DataOut1' or 'M*.DataOut2', or 'M*.DataOut'
<NRf>: Set periodic jitter frequency.
Return Range 1 kHz to 500 MHz
Description This command sets the frequency of the periodic jitter for the specified
output.
The “(*)” suffix specifies which of the two periodic sources (1 or 2) for the
specified channel to use. If a suffix is not specified, the suffix 1 is assumed.
Acceptable units include Hz, kHz, MHz and exponents (for example, 1E3 is
the same as 1,000 Hz).
This SCPI is applicable for M8041A, M8051A, M8061A, M8062A and
M8045A.
This SCPI is also available on M8195A for DataOut1 to 4.
Example :JITT:HFR:PER:FREQ ‘M1.DataOut2’, 20.0e6

Table of Contents

Other manuals for Keysight Technologies J-BERT M8020A

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Keysight Technologies J-BERT M8020A and is the answer not in the manual?

Keysight Technologies J-BERT M8020A Specifications

General IconGeneral
BrandKeysight Technologies
ModelJ-BERT M8020A
CategoryControl Unit
LanguageEnglish

Related product manuals