Keysight M8070A Programming Guide 163
SCPI Command Reference 5
[:SOURce]:JITTer:HFRequency:RANDom[:STATe][?]
Syntax [:SOURce]:JITTer:HFRequency:RANDom[:STATe] ‘identifier’ <ON|OFF|1|0>
[:SOURce]:JITTer:HFRequency:RANDom[:STATe]? ‘identifier’
Input
Parameters
‘identifier’: 'M*.DataOut1', 'M*.DataOut2', ‘M1.ClkOut’, or 'M*.DataOut'
<ON|OFF|1|0>: Enable/disable random jitter source.
Return Range 0|1
Description This command enables/disables the generation of random jitter.
This SCPI is applicable for M8041A, M8051A, M8061A, M8062A and
M8045A.
This SCPI is also available on M8195A for DataOut1 to 4.
Example :JITT:HFR:RAND ‘M2.DataOut2’, on
[:SOURce]:JITTer:HFRequency:RANDom:AMPLitude[?]
Syntax [:SOURce]:JITTer:HFRequency:RANDom:AMPLitude ‘identifier’ <NRf>
[:SOURce]:JITTer:HFRequency:RANDom:AMPLitude? ‘identifier’
Input
Parameters
‘identifier’: 'M*.DataOut1' or 'M*.DataOut2', or 'M*.DataOut'
<NRf>: Set random jitter amplitude.
Return Range 0 uUI to 13.08 mUI or 0 ps to 78.57 ps
Description This command sets the root mean square (rms) RJ amplitude in seconds or
unit intervals based on the selected amplitude unit. The units are set using
the [:SOURce]:JITTer:HFRequency:UNIT command.
This SCPI is applicable for M8041A, M8051A, M8061A, M8062A and
M8045A.
This SCPI is also available on M8195A for DataOut1 to 4.
Example :JITT:HFR:RAND:AMPL ‘M2.DataOut2’, 0.013
[:SOURce]:JITTer:HFRequency:RANDom:FILTer[:LPASs][?]
Syntax [:SOURce]:JITTer:HFRequency:RANDom:FILTer[:LPASs] ‘identifier’
<OFF|LP100|LP500>
[:SOURce]:JITTer:HFRequency:RANDom:FILTer[:LPASs]? ‘identifier’