168 Keysight M8070A Programming Guide
5 SCPI Command Reference
[:SOURce]:JITTer:HFRequency:SPECtrally:FILTer[:LPASs][:STATe][?]
Syntax [:SOURce]:JITTer:HFRequency:SPECtrally:FILTer[:LPASs] [:STATe]
‘identifier’ <ON|OFF|1|0>
[:SOURce]:JITTer:HFRequency:SPECtrally:FILTer[:LPASs] [:STATe]?
‘identifier’
Input
Parameters
‘identifier’: 'M*.DataOut1' or 'M*.DataOut2'
<ON|OFF|1|0>: Enable/disable low-pass filter.
Return Range 1|0
Description Enables/disables the 100 MHz low-pass filter for spectrally distributed
random jitter.
This SCPI is applicable for M8041A, M8051A, M8061A and M8062A.
Example :JITT:HFR:SPEC:FILT ‘M2.DataOut2’, off