210 Keysight M8070A Programming Guide
5 SCPI Command Reference
Return Range OFF|IDLE|EXT
Description This command enables/disables the electrical idle feature for the Data
Output. The state can be OFF, IDLE or EXTernal.
This SCPI is applicable for M8061A and M8062A.
Example :OUTP:EIDL ‘M2.DataOut’, EXT
:OUTPut:DATA:XOVer[?]
Syntax :OUTPut:DATA:XOVer ‘identifier’, <NRf>
:OUTPut:DATA:XOVer? ‘identifier’
Input
Parameters
‘identifier’: 'M*.DataOut1', 'M*.DataOut2', or 'M*.DataOut'
<NRf>: Specify an eye crossover.
Return Range For M8041A and M8051A: 10% to 90%
For M8061A and M8062A: 30% to 70%
Description This command sets the eye crossover of the transmitter signal at the DATA
OUT/-DATA OUT connectors. Crossover is defined for NRZ signals.
This SCPI is applicable for M8041A, M8051A, M8061A and M8062A.
Example :OUTP:DATA:XOV ‘M1.DataOut2’, 25
:OUTPut:DATA:F2Jitter[?]
Syntax :OUTPut:DATA:F2Jitter ‘identifier’, <NRf>
:OUTPut:DATA:F2Jitter? ‘identifier’
Input
Parameters
‘identifier’: 'M*.DataOut1', 'M*.DataOut2', or 'M*.DataOut'
<NRf>: Set the f/2 jitter.
Return Range -20 ps to +20 ps
Description This command sets the f/2 jitter at the output in seconds. Acceptable units
include ps and exponents (for example, -10e-12 is the same as -10 ps).
This query returns the present setting.
This SCPI is applicable for M8041A, M8051A, M8061A, M8062A and
M8045A.
Example :OUTP:DATA:F2J ‘M1.DataOut2’, -10e-12