232 Keysight M8070A Programming Guide
5 SCPI Command Reference
This SCPI is applicable for M8195A and M8196A.
Example :OUTP:EMB:SPAR:IPOR ‘M1.DataOut1’, 1
:OUTPut:EMBedding:SPARameter:OPORt[?]
Syntax :OUTPut:EMBedding:SPARameter:OPORt ‘identifier’, <NRf>
:OUTPut:EMBedding:SPARameter:OPORt ‘identifier’
Input
Parameters
‘identifier’:'M*.DataOut1’,‘M*.DataOut2’,‘M*.DataOut3’,or ‘M*.DataOut4’
Description This command selects the output port in the S-Parameter profile.
The query returns the present setting.
This SCPI is applicable for M8195A and M8196A.
Example OUTP:EMB:SPAR:OPOR ‘M1.DataOut1’, 2