Keysight M8070A Programming Guide 235
SCPI Command Reference 5
:INPut:DATA:BRMode[?]
Syntax :INPut:DATA:BRMode ‘identifier’, < 0 | 1 | ON | OFF>
:INPut:DATA:BRMode? ‘identifier’
Input
Parameters
‘identifier’: 'M*.DataIn1' or 'M*.DataIn2'
Range 0 | 1 | ON | OFF
Description This command enables/disables the bit recovery mode. In BRM, the error
detector does not expect any specific data. This mode can be used if the
incoming data is completely unknown.
Example :INP:DATA:BRM 'M1.DataIn1',ON
NOTE
The bit recovery mode is only available with CDR.