238 Keysight M8070A Programming Guide
5 SCPI Command Reference
:INPut:EQUalization:LEVel[?]
Syntax :INPut:EQUalization:LEVel 'Identifier', <NRf>
Input
Parameters
:INPut:EQUalization:LEVel? 'Identifier',
‘identifier’: 'M*.DataIn'
The specified number has a range from 0 – 15.
Return Range 0 –
15
Description This command sets an equalization level in order to compensate
the loss characteristic of an incoming pulse.
It has a range of 0 to 15 pre-defined levels where ‘0’ denotes no
equalization is done.
T
his SCPI is only applicable for M8046A.
Example :INP:EQU:LEV ‘M1.DataIn’,12
:INP:EQU:LEV? ‘M1.DataIn’
:INPut:POLarity[?]
Syntax :INPut:POLarity ‘i
dentifier’, <NORMal|INVerted>
:INPut:POLarity? ‘identifier’
Input
Parameters
‘identifier’: 'M*.DataIn1', 'M*.DataIn2', or 'M*.DataIn'
<NORMal|INVerted>: Set input polarity.
Return Range NORM|INV
Description This command sets the input polarity of the specified input to either
NORMal or INVerted.
This SCPI is applicable for M8041A, M8051A, M8061A, M8062A and
M8046A.
Example :INP:POL ‘M1.DataIn1’, INV
:INPut:CMVoltage[?]
Syntax :INPut:CMVoltage ‘i
dentifier’, <NRf>
:INPut:CMVoltage? ‘identifier’
Input
Paramet
ers
‘identifier’: 'M*.DataIn1' or 'M*.DataIn2'
<NRf>: Set common mode voltage.

Table of Contents

Other manuals for Keysight Technologies J-BERT M8020A

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Keysight Technologies J-BERT M8020A and is the answer not in the manual?

Keysight Technologies J-BERT M8020A Specifications

General IconGeneral
BrandKeysight Technologies
ModelJ-BERT M8020A
CategoryControl Unit
LanguageEnglish

Related product manuals