Keysight M8070A Programming Guide 293
SCPI Command Reference 5
:PLUGin:ERATio:SHOW:RVMode[?]
Syntax :PLUGin:ERATio:SHOW:RVMode ‘identifier’, <DET|SUMM>
:PLUGin:ERATio:SHOW:RVMode? ‘identifier’
Input
Parameters
‘identifier’: Specify the measurement name.
<DET|SUMM>: Select measurement results view mode.
Return Range DET|SUMM
Description This command sets the measurement results view mode to detailed or
summary when viewing the results using the
:PLUGin:ERATio:FETCh:DATA? command. This mode can be changed
during a measurement or after a measurement has completed. The default
is summary mode.
DET (detailed) sets the mode to return the error ratio, compared bits,
errored bits, errored zero ratio, compared zeroes, errored zeroes, errored
one ratio, compared ones, errored ones, etc.
SUMM (summary) sets the mode to return the error ratio, compared bits,
errored bits, etc.
This SCPI is applicable for M8041A, M8051A, M8061A, M8062A and
M8046A.
Example :PLUG:ERAT:SHOW:RVM ‘MyMeasurement’, DET