Keysight M8070A Programming Guide 315
SCPI Command Reference 5
:PLUGin:OTIMing:SHOW:VSCale[?]
Syntax :PLUGin:OTIMing:SHOW:VSCale ‘identifier’, <LOG|LIN>
:PLUGin:OTIMing:SHOW:VSCale? ‘identifier’
Input
Parameters
‘identifier’: Specify the measurement name.
<LOG|LIN>: Specify the vertical axis scale.
Return Range LOG|LIN
Description This command specifies the vertical BER axis scale and associates it with a
specific measurement name identifier. If LOG is specified then the BER
values are in terms of a logarithmic scale. If LIN is specified then the BER
values are in terms of a linear scale. The query returns the current value.
This SCPI is applicable for M8041A, M8051A, M8062A and M8046A.
Example :PLUG:OTIM:SHOW:VSC ‘MyMeasurement’, LOG
:PLUGin:OTIMing:SHOW:SGLegends
Syntax :PLUGin:OTIMing:SHOW:SGLegends 'Identifier', <0|1|OFF|ON>
:PLUGin:OTIMing:SHOW:SGLegends? 'Identifier'
Input
Parameters
Identifier: 'MyMeasurement'
<0|1|OFF|ON>: Specify the show/hide state for graph legends.
Return Range 0|1
Description This command shows/hides the graph legends.
This SCPI is applicable for M8041A, M8051A, M8062A and M8046A.
Example :PLUGin:OTIMing:SHOW:SGLegends 'MyMeasurement', 1
:PLUGin:OTIMing:CATalog?
Syntax :PLUGin:OTIMing:CATalog?
Description This command returns a list of all created output timing measurement
names currently available for measuring.
This SCPI is applicable for M8041A, M8051A, M8062A and M8046A.