Keysight M8070A Programming Guide 319
SCPI Command Reference 5
:PLUGin:OTIMing:STEP
Syntax :PLUGin:OTIMing:STEP ‘identifier’
Input
Parameters
‘identifier’: Specify the measurement name to step.
Description This command allows you to step through an output timing measurement,
addressed by the measurement name identifier, that was stopped using
the BREak command.
This SCPI is applicable for M8041A, M8051A, M8062A and M8046A.
Example The following example triggers a single output timing measurement step
of the measurement addressed with the measurement name identifier
called ‘MyOutputTiming’:
:PLUG:OTIM:STEP ‘MyOutputTiming’